Comet Data Review: SBN Sept 28, 1998: 3-5 PM EDT Problems for discussion At end of session will decide on data as accepted, rejected, or action(liens) General (items will at end plus whatever) List of changes/fixes posted Monday, Sept 28, under GRAYZECK comments ICE ( Ion Composition Instrument and Ultra Low Energy Charge Analyser) ---------------------------------------------------------------------- 1. Replace ICE mission catalog file? 2. ULECA: Remove extra parameters in the ULECA selected tables and remove all but M21, M11, M31 rates in ULECA selected tables Remove all data for ULECA except for sept 9-13 3. ICI: create an index for ICI data arrays and include data for Sept 9-13 or remove all ICI arrays except for 10 periods on Sept 11 Digitize other ICI figures (beside figure 2)? (permission) Include instrument papers for ICE experiments? all figures? (note permission granted through IEEE) Giotto (Giotto Radio Experiment) -------------------------------- Earlier (1994) GRE reduced data ingested; Dick Simpson (reviewer) has now submitted the raw files for GRE as supplement 1. Is GRE documentation sufficient? IHW Near Nucleus Studies Network (NNSN) replacement images ---------------------------------------------------------- Identified in 1993 review as corrupted, now replaced 1. How to notify of new data; Web page for SBN now carries errata file. Would probably include the new files as replacement under "selected" IR Photometry data (Gehrz) ------------------------- supplement to IHW, supplied by Gehrz/Mergen following 1993 review 1. Put source of data in labels? 2. current blanks should be converted to INVALID_CONSTANT? 3. do we need a HOST catalog file to describe UM 0.6 m (not in IHWHOST) OUTBURST ESO --- 1. are the filenames acceptable when compared to the obs log (eso_data.asc)? 2. put eso_flux table (text) with the "flux" files/directories? 3. derived_max and min values are mixture of integer/reals? conform? 4. Is reference acceptable to describe processing technique in the esods file? 5. are directory names (flux, cal, sum, sub) well explained (aareadme?) 6. do we need to specific the NTT nights for emmiinst and susiinst files? CTIO ---- 1. filter have array information, what do values mean? (e.g., R(3 6)) 2. The process of flatfield, star composite, "cleaned" or "t" composite and star frame subtraction is explained in the CTIODS file? No reference? 3. (0409) files H_S and HALLEY_S differ in processing; look similar? name? UH -- 1. Use of SA in standard star; does this mean Selected Area (Landolt 1992)? 2. same as 2 for CTIO, UHDS file? All outburst ------------ 1. How to resolve name for filters? Johnson V, V, or table? 2. Do exposure times need to be uniform integer or real? What about values of 0. and 60.? Do the float values need to be uniform? 3. Are ESO/CTIO/UH manuals as references (not URL) acceptable? 4. Do we need the CTIO, ESO, UH host files (IHWHOST?) 5. abbreviations for in Exposure_duration ok? (SL9, others?) Database Lowell (locd) ------------- 1. Are the comet abbreviations in LOCD useful? should be in all/some tables? 2. can ASCII column headings be included in a PDS table? 3. format of prepend table needs fixing, make the k,sigma value appear as a pair? MOFCS ----- 1. resolve problem with difference between flux and column density values when sorted by observing run? 2. gather intermediate parameters from Cochran et al (1992)? all? ABSMAG (Vsekh) ------ 1. apply errata file to table, check with original translation? General 1. Is it a problem to mix PDS (version)catalog files from older sets? 2. best way to assemble 4 data groups (GZ CD, Outburst CD, web, database)? 3. Is a utility to READIMAGE for FITS header information needed?