DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0 Catalog ======= o In the dataset.cat file description, please add full citations to the Calibration papers (i.e., as footnotes in the text – in addition to the REFERENCE objects that also exist). o In dataset.cat. the CITATION_DESC year must be '2014' since this is when the data were reviewed and released to the public. o In dataset.cat, the DESCRIPTION is lacking the usual summary of why the data were taken in the first place. A sentence or two should be added to address this. o The EPOXI mission.cat description misstates the wavelength coverage range of the HRII instrument. This should be corrected. o Voldesc.cat references "EARTH.CAT", which is not in the data set. The reference should be removed from voldesc.cat. Documents ========= o Ensure these data sets have the latest versions of these document files: day_of_year_calendar.lbl epoxi_cal_pipeline_summ.lbl epoxi_sis.lbl instruments_hampton.lbl pdsdd_epoxi.lbl quaternion_desc.lbl o In epoxi_sis.pdf: - This document says labels for HRIV, MRI, and ITS level 3/4 data, PDS keyword PROCESSING_HISTORY_TEXT contain FLAT_PRO= FLATCONS= FLATTEMP= CALWINDW= CALWINPY= but the sample labels in the SIS's 4.4.4.1 and 4.4.4.2 do not. - p. 27: "DIF-L-HRII-3_4-EPOXI-LUNAR-CALS-V1.0" should have a / not a _ i.e. "DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0" - epoxy_sis.pdf pages 47-9 the figures are misaligned with the text. This needs to be corrected in every copy of the document in all data sets. o There are summary files with names like “hriv_3_4_epoxi_garrad.pdf”. In at least some of these labels in some data sets, the Julian Date field is described as being in the form “YYYYMMDD”. This needs to be fixed if it applies to this data set. o In places that describe the file naming convention, there needs to be a clear indication of which time (beginning, middle, end) is used for creating the file name. o Need more description of "spectral scanning mode". Could be in the dataset.cat DESCRIPTION, if it's short, or in a separate document that can be referenced as needed. o AAREADME.TXT mentions a non-existent EXTRAS/ directory. CALIB/ ====== o In /abscalir/hriir_071004_1_4_999.lbl, typo: Line 1: wPDS_VERSION_ID = PDS3 o In flat/hriir_050112_8_0_0.lbl: Missing PDS_VERSION_ID = PDS3 (required first line) o In lindn/*.lbl: AXIS_NAME = ("LINE_SAMPLES", "LINES", "PER_PIXEL_LINEARITY_COEFFS") is legal, but "SAMPLE" and "LINE" (singular) are much more common. DATA/ ===== o One reviewer (Lucas Paganini) showed a sample of stacked RAD data that show an interference pattern caused by the beam splitter that would not be expected in calibrated data. This needs investigating and explaining. Example file: 2009-352, exposure 100000 image 2. (Tony Farnham will investigate.) o One reviewer requested separating the data by frame size, which corresponds to science/calibration objectives.