DIF-C-HRII-3/4-9P-ENCOUNTER-V3.0 Catalog ======= o In the dataset.cat file description, please add full citations to the Calibration papers (i.e., as footnotes in the text – in addition to the REFERENCE objects that also exist). o In dataset.cat. the CITATION_DESC year must be '2014' since this is when the data were reviewed and released to the public. o Please note in the dataset.cat Confidence Level Note that transient anomalous pixels may be present in the data. o In dataset.cat, the description of the east flip for lookback images is incorrect. (In the paragraph beginning, "Using this convention for Tempel 1 approach images...".) See Jianyang's slide 17 for the geometry and correct orientation. o In dataset.cat - The DATA_SET_TERSE_DESC says that the instrument was HRIV not HRII. - line 100: typo: Change "KLAASENTAL2005" to "KLAASENETAL2005". o The required instrument_host catalog file is missing for the impactor. o In voldesc.cat: - This data set is NOT an amalgam of physical volumes, so the VOLUME_ID must be valid - it may not end in 'X'. - VOLUME_VERSION_ID must be set with respect to the final, valid VOLUME_ID. Documents ========= o Ensure these data sets have the latest versions of these document files: day_of_year_calendar.lbl epoxi_cal_pipeline_summ.lbl epoxi_sis.lbl instruments_hampton.lbl pdsdd_epoxi.lbl quaternion_desc.lbl o In epoxi_sis.pdf: - This document says labels for HRIV, MRI, and ITS level 3/4 data, PDS keyword PROCESSING_HISTORY_TEXT contain FLAT_PRO= FLATCONS= FLATTEMP= CALWINDW= CALWINPY= but the sample labels in the SIS's 4.4.4.1 and 4.4.4.2 do not. - p. 27: "DIF-L-HRII-3_4-EPOXI-LUNAR-CALS-V1.0" should have a / not a _ i.e. "DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0" - epoxy_sis.pdf pages 47-9 the figures are misaligned with the text. This needs to be corrected in every copy of the document in all data sets. o There are summary files with names like “hriv_3_4_epoxi_garrad.pdf”. In at least some of these labels in some data sets, the Julian Date field is described as being in the form “YYYYMMDD”. This needs to be fixed if it applies to this data set. o In places that describe the file naming convention, there needs to be a clear indication of which time (beginning, middle, end) is used for creating the file name. CALIB/ ====== o In dark/hriir_050622_3_2_6002201000.lbl, SAMPLE_BITS = "32" should not have quotes around the numeric value. o In specmap/*lbl: AXIS_NAME = ("SAMPLES", "LINES", "MEASUREMENT") is legal, but "SAMPLE" and "LINE" (singular) are much more common. o The files: abscalir/hriir_050112_16_3_999.lbl flat/hriir_050112_8_0_0.lbl are missing the required first line, PDS_VERSION_ID = PDS3 o The sunspec/ subdirectory is not listed in the calinfo.txt file, and must be.