Liens List from New Horizons P3 June 2017 review for: NH-P-PEPSSI-2-PLUTO-V3.0 NH-P-PEPSSI-3-PLUTO-V3.0 File: calibrated dataset.cat --> file should be updated as requested in the March delta review- critical information has been added to the ICD. Remove statements about preliminary calibration and not doing science relying on absolute flux values - replace with text from ICD. --> DATA_OBJECT_TYPE = IMAGE. While the label does contain a dummy image object, the data are stored in tables. File: dataset.cat --> Spelling errors in dataset.cat file need to be fixed. line 108 manuevers. line 414 occurred. line 417 docmentation --> line 61: In this delivery "V3.0" was changed to "V2.0". It appears that it should actually be "V3.0" as it was originally. File: PEPSSI.CAT --> still states that "Level 3 data should not be used as is to conduct science that is relying on absolute fluxes for scientific interpretation unless the user determines the fluxes independently." Remove that statement about preliminary calibration and replace with text from ICD File: introdoc.pdf --> Spelling error under "Data Intrduction:" on second line: "tfor" should be "for". --> In "Data Introduction", under 'Operation and measurements' on third line it says "TOF start and identifying the sector and therefore". It should be "TOF start (identifying the sector) and therefore". --> Keyword not replaced with instrument name. Missing text on the front page File: soc_inst_icd.pdf --> Spelling error: Under "PEPSSI Ectronics Description", "custom electronic" should be "custom electronics" File: data/*.fit --> NASAView has issue with the calibrated data beyond the primary extension. File: nh-p-pepssi-3-pluto-v3.0/calib/calpars/calpar_columns.fmt --> The lines are 80 chars but should be 78. File: nh-p-pepssi-2-pluto-v3.0/data/20150701_029808/pep_0298014718_0x691_eng.lbl, nh-p-pepssi-3-pluto-v3.0/data/20150701_029808/pep_0298014718_0x691_sci.lbl --> 1.001 second gap between files, and that gap is usually .001 seconds. File: nh-p-pepssi-3-pluto-v3.0/data --> FLUX HDU Rate Boxes- Proton CPS: Energetic particle data are direction sensitive. It is not clear what happening in the direction of sectors 4&5 and also top channel looks bad in all the sectors. These need to be fixed --> FLUX HDU B Rate Boxes - Proton UNC: Uncertainties in sectors 0 to 1 do not appear to reflect the data in those sectors --> FLUX HDU L Rate Boxes - Proton DNF: Highest energy looks contaminated in sectors 0 to 3 and sector 4&5 contaminated. In sector 5, the flux is higher than expected. These issues need to be fixed File: index/index.lbl --> File breaks down after column 11 for accurately describing the index table. File: index/slimindx.tab & .lbl --> Slim index file has 4 columns but the label describes 3 - cut and paste error when trimming the index file, grabbed too much real estate. There are column labeling errors in the index file which need to be checked and resolved