Lucy RSS Sample Data Products Review Dustin Buccino, 05/17/2023 This review is exclusively about the data labels themselves and not verifying the scientific integrity of the provided data. Future reviews may have a scope beyond just the data labels. lucy_2022_285_104518_2022_285_165503_53.xml The data file is sorted into groups by data type like expected. I found no issues with the Table descriptors looking manually. Specific Comments: The label fails validate, primarily from content validation errors associated with "Value does not match its data type ASCII_String." I believe the reason is because there are leftover records with a secondary CHDO data type of C044. This data descriptor is indicating the SFDU was marked invalid by the DSN and more importantly is not documented in the TRK-2-34 Software Interface Spec. In the past, the DSN Radiometric Data Conditioning Team (RMDC) would have deleted these records before submitting to oscarx. In my deliveries (Juno, InSight, etc), I remove these SFDUs prior to delivery to avoid invalid data going to PDS. As a test, I deleted those SFDUs, and re-labeled the file with my software and there were no issues. I can provide the modified data file and sample label if desired. Internal LID documentation reference (line 118) urn:nasa:pds:radiosci.documentation:dsn.trk-2-24:2006-03-15 Is for a different data format. The correct reference should be: urn:nasa:pds:radiosci.documentation:dsn.trk-2-34 Someone from the PDS SBN should verify the file extension. I believe the requirement for binary data files is "*.dat". lucy_2022_274_2022_305_ion.xml This is a standard DSN ionosphere calibration file. The label is formed well and I have no comments.